Four control methods are
included:
- Standard V/F control
- V/F control with PG feedback
- Sensorless flux vector control
- Flux vector current control with PG feedback
Simply select the parameters, EI-Super N can be applied to a wide range
of applications from servo-like precision machinery to multiple
motor drives.
Factory presets default to sensorless vector control type, but it can
be configured to the V/F control mode for applications requiring
multiple motors on one device, or set to flux vector current
control mode (with PG) for hughly precise vector operation.
(PG-B interface card is optional)
Note: at low speed, high torque and continuous operation, a forced
cooling special motor must be used |