Inverter Model EI-Super N
|
001L
|
002L
|
003L
|
005L
|
007L
|
010L
|
015L
|
020L
|
025L
|
030L
|
040L
|
050L
|
060L
|
075L
|
100L
|
150L
|
|
Max. applicable motor output
(kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
110
|
|
Inverter Capacity Hp
|
1
|
2
|
3
|
5
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
75
|
100
|
150
|
|
Rated Output Current A
|
6
|
8
|
11
|
17.5
|
25
|
33
|
49
|
64
|
80
|
96
|
130
|
160
|
183
|
224
|
300
|
450
|
|
Protective Level
|
Enclosed wall-mounted type
(NEMA1) IP20
|
|
Power Supply
|
Max. Output Voltage
|
3-phase 200/208/220, 50/60Hz,
230V/60Hz
|
|
Rated input Voltage and
frequency
|
3-phase 200/208/220V 50Hz,
200/208/220/230V 60Hz
|
|
Allowable Voltage Fluctuation
|
+10%
|
|
Allowable Frequency Fluctuation
|
+5%
|
|
Max. Output Voltage
|
3-phase 200/208/220/230V
Proportional to input voltage
|
|
Rated Output Frequency
|
Up to 400Hz available by
programming
|
|
Control Characteristics
|
Control Method
|
Sine wave PWM type, four
control methods: (1) v/f (2) v/f with PG (3) open loop
vector (4) flux vector
|
|
Starting Torque
|
150% / 1Hz (150%/or/min
with PG)
|
|
Speed Control Range
|
1:100 (1:1000 with PG)
|
|
Speed Control Accuracy
|
± 0.2% (± 0.02% with PG)
|
|
Speed Response
|
5 Hz (30Hz with PG)
|
|
Torque Limit
|
Available (Parameter setting,
4 steps can be changed)
|
|
Torque Accuracy
|
± 5%
|
|
Torque Response
|
20Hz (40Hz with PG)
|
|
Frequency Control Range
|
0.1 to 400Hz
|
|
Frequency Accuracy
|
Digital command: 0.01% (-10ºC
to +40ºC), Analog command: 0.1% (25ºC ± 10ºC)
|
|
Frequency Resolution
|
Digital operator reference: ± 0.01Hz
Analog reference: 0.05Hz/
60Hz (11bit+code)
|
|
Output Frequency Resolution
|
0.01 Hz
|
|
Overload Capacity
|
150% of rated output current
for 1 minute
|
|
Frequency Setting Signal
|
-10 to 10 V, 0 to 10V, 4
to 20mA
|
|
Accel / Decel Time
|
0.01 to 6000.0 sec (Accel
/ decel time setting independently, 4 steps available)
|
|
Braking Torque
|
Approx.20%
|
|
Protective function
|
Motor Overload Protection
|
Protected by electronic thermal
overload relay
|
|
Instantaneous Overcurrent
|
Motor coasts to a stop at
approx.200% of inverter rated current
|
|
Blown Fuse Protection
|
Motor coasts to a stop by
blown-fuse
|
|
Overload
|
Motor coasts to a stop after
1 minute at 150% of rated output current
|
|
Overvoltage
|
Motor coasts to a stop if
converter output voltage exceeds 400V
|
|
Undervoltage
|
Motor coasts to a stop if
converter output voltage drops to 200V or below
|
|
Momentary Power Loss
|
Immediately stop by 15 ms
and above momentary power loss (factory setting).
Continuous
operation during power loss less than 2 sec is equipped as standard
|
|
Heatsink Overheat
|
Protected by thermistor
|
|
Stall Prevention
|
Stall Prevention during accel
/ decel and constant speed operation
|
|
Ground Fault
|
Protected by electronic circuit
(overcurrent level)
|
|
Power Charge Indication
|
Charge LED stays ON until
bus voltage drops below 50V
|
|
Environment
|
Ambient Temperature
|
-10ºC to +40ºC (enclosed
wall-mounted type), -10ºC to +45ºC (open chassis type)
|
|
Humidity
|
90% RH or less
|
|
Storage Temperature
|
-20ºC to +60ºC
|
|
Location
|
Indoor (protected from corrosive
gases and dust)
|
|
Elevation
|
1000 m or less
|
|
Vibration
|
9.8 1m/ S² (1G) less than