Go to the Home page  
EI-Super N Series
| CONTROL | 220V | 440V | CONNECT | PRESETS | DIMENSIONS |
 


 Get the free Acrobat reader for PDF documents


220v Specifications

Inverter Model EI-Super N

001L

002L

003L

005L

007L

010L

015L

020L

025L

030L

040L

050L

060L

075L

100L

150L

Max. applicable motor output (kW)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

110

Inverter Capacity Hp

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

150

Rated Output Current A

6

8

11

17.5

25

33

49

64

80

96

130

160

183

224

300

450

Protective Level

Enclosed wall-mounted type (NEMA1) IP20

Power Supply

Max. Output Voltage

3-phase 200/208/220, 50/60Hz, 230V/60Hz

Rated input Voltage and frequency

3-phase 200/208/220V 50Hz, 200/208/220/230V 60Hz

Allowable Voltage Fluctuation

+10%

Allowable Frequency Fluctuation

+5%

Max. Output Voltage

3-phase 200/208/220/230V Proportional to input voltage

Rated Output Frequency

Up to 400Hz available by programming

Control Characteristics

Control Method

Sine wave PWM type, four control methods: (1) v/f (2) v/f with PG (3) open loop vector (4) flux vector

Starting Torque

150% / 1Hz (150%/or/min with PG)

Speed Control Range

1:100 (1:1000 with PG)

Speed Control Accuracy

± 0.2% (± 0.02% with PG)

Speed Response

5 Hz (30Hz with PG)

Torque Limit

Available (Parameter setting, 4 steps can be changed)

Torque Accuracy

± 5%

Torque Response

20Hz (40Hz with PG)

Frequency Control Range

0.1 to 400Hz

Frequency Accuracy

Digital command: 0.01% (-10ºC to +40ºC), Analog command: 0.1% (25ºC ± 10ºC)

Frequency Resolution

Digital operator reference: ± 0.01Hz
Analog reference: 0.05Hz/ 60Hz (11bit+code)

Output Frequency Resolution

0.01 Hz

Overload Capacity

150% of rated output current for 1 minute

Frequency Setting Signal

-10 to 10 V, 0 to 10V, 4 to 20mA

Accel / Decel Time

0.01 to 6000.0 sec (Accel / decel time setting independently, 4 steps available)

Braking Torque

Approx.20%

Protective function

Motor Overload Protection

Protected by electronic thermal overload relay

Instantaneous Overcurrent

Motor coasts to a stop at approx.200% of inverter rated current

Blown Fuse Protection

Motor coasts to a stop by blown-fuse

Overload

Motor coasts to a stop after 1 minute at 150% of rated output current

Overvoltage

Motor coasts to a stop if converter output voltage exceeds 400V

Undervoltage

Motor coasts to a stop if converter output voltage drops to 200V or below

Momentary Power Loss

Immediately stop by 15 ms and above momentary power loss (factory setting).
Continuous operation during power loss less than 2 sec is equipped as standard

Heatsink Overheat

Protected by thermistor

Stall Prevention

Stall Prevention during accel / decel and constant speed operation

Ground Fault

Protected by electronic circuit (overcurrent level)

Power Charge Indication

Charge LED stays ON until bus voltage drops below 50V

Environment

Ambient Temperature

-10ºC to +40ºC (enclosed wall-mounted type), -10ºC to +45ºC (open chassis type)

Humidity

90% RH or less

Storage Temperature

-20ºC to +60ºC

Location

Indoor (protected from corrosive gases and dust)

Elevation

1000 m or less

Vibration

9.8 1m/ S² (1G) less than 20Hz, up to 1.96 m/ S² (0.2G) at 20 to 50 Hz

Note: (1) Max. applicable motor referring to standard 4 poles motor.
           (2) High storage temperature may damage the capacitors in inverter.

  to top of page
 
 

 About Us | AC Inverters | DC/AC Inverters | Electric Scooters
 Ozone Products | Lighting | Other Products | Contact Us

Copyright © 2007 - Rich Electric Company Limited
Ph: +886-6-2541000 / +61-2-4353-3366      Fax: +886-6-2540493 / +61-2-4353-3367
Email: info@rich-electric.com

Website Design
by
Shadow Group
Website Design by Shadow Group