| Terminal V1 |
0 volt or control common (connected to
-DC of power circuit) (isolated) |
| Terminal V2 |
Speed reference input from 0 to 5 volt or 0 to 10 volt
or 4-20mA, select by jumper J3 |
| Terminal V3 |
+5 volt output for the 5k Speed potentiometer |
| Terminal FOR |
Forward run when CLOSED; stopped when OPEN |
| Terminal REV |
Reverse run when CLOSED; stopped when OPEN |
| Terminal RESET |
Fault Reset when CLOSED |
| Terminal STOP |
In 3-WIRE mode, when CLOSED then allow to run |
| Terminal FM |
Analog output signal for Frequency output |
Terminal V0 |
Control Common |
| Terminal TRIP |
Fault output (open collector output) |
| Terminal FUNC |
Multi-function output (Drive running or Drive speed
agree, select by switch S1) |
| Terminal COM |
TRIP, FUNC fuction common |
| Terminals |
Switch S3 |
Action 0V connected |
Disconnect from 0V |
FOR
REV
STOP
RESET |
2-wire mode
switch S3 ON |
Run Forward |
Stop |
| Run Reverse |
Stop |
| Allow to Run |
Disable output |
| Reset |
No action |
FOR
REV
STOP
RESET |
3-wire mode
switch S3 OFF |
Run Forward |
No action |
| Run Reverse |
No action |
| Allow to Run |
Disable output |
| Stop and Reset |
No action |
Speed
reference select: jumper J3
|