Specification
|
Model |
EI-MINI
|
|
SIZE 1
|
SIZE 2
|
|
SP2
|
SP4
|
SP7
|
LP2
|
LP4
|
LP7
|
GP4
|
GP7
|
G1P5
|
FP7
|
F1P5
|
|
Power rating UP to KW (HP)
|
0.2 (1/4)
|
0.4 (1/2)
|
0.7 (1)
|
0.2 (1/4)
|
0.4 (1/2)
|
0.7 (1)
|
0.4 (1/2)
|
0.7 (1)
|
1.5 (2)
|
0.7 (1)
|
1.5 (2)
|
|
AC Input Voltage
|
1ø 100-120 (VAC)
|
1ø 200-240 (VAC)
|
3ø 200-240 (VAC)
|
3ø 380-440 (VAC)
|
|
AC Input Frequency
|
45~60 Hz
|
|
AC Output Voltage
|
0 to 220V 3ø Output
|
0 to Input Voltage, Three-Phase
Output
|
|
AC Output Frequency
|
0 to 50/60Hz or 0 to 100/120Hz
|
|
AC Output Current (100%)
|
1.5A
|
2.4A
|
4A
|
1.5A
|
2.4A
|
4A
|
2.4A
|
4A
|
7A
|
2.4A
|
4A
|
|
Overload Capacity
(150% for 60 seconds)
|
2.2A
|
3.6A
|
6A
|
2.2A
|
3.6A
|
6A
|
3.6A
|
6A
|
10.5A
|
3.6A
|
6A
|
|
PWM
Switching Freq.
|
16KHz
|
|
Storage Temperature
|
-40ºC to + 65ºC (-40ºF to 149ºF )
|
|
Operating Temperature
|
0ºC to + 50ºC (32ºF to 122ºF
)
|
|
Operating Modes
|
Speed Mode, 2-Wire and 3-Wire Modes
|
|
Stop Modes
|
Ramp Stop, or DC Injection
|
|
Load
|
Constant Torque or Fan (Variable Torque)
|